• ANALOG OUTPUT SIGNAL CONDITIONERS ATEX APPROVED
  • ALA-5   ATEX Approved 4-20mA Amplifier
    for Hazardous Zones 0, 1 & 2
  • ICA5-ATEX Embedded ATEX Approved
    Strain gauge converter 4-20mA
  • Introduction
  • Specifications
  • Dimensions
  • Downloads
  • Related Products
  • FAQ's
  • Buy Now!

The ALA5 is an ATEX approved strain gauge/load cell amplifier designed for operation within hazardous zones 0,1 & 2.

The high performance amplifier provides 2-wire 4-20mA current loop output and connects in-line for a range of signal conditioning for strain gauges, load cells, pressure and torque transducers. Intrinsically safe to EN60079-11 (previously EN 50020) standards.

The device can be connected to ATEX approved equipment within the hazardous zone or to non-approved ATEX equipment outside the hazardous zone provided that a suitable barrier is used.

Designed for fitting in-line to strain gauge sensors such as load cells, the amplifier is housed within a stainless steel IP67 NEMA 4 EMC protected enclosure and is supplied with 1m strain gauge cable and 5m output cable.

An OEM option is available for customers wishing to embed the ATEX amplifier within the sensor. Please note: the ICA5ATEX is approved for incorporation into load cells and other enclosures. Please contact us to discuss your requirements.

Evaluation units now available for trial and evaluation at low cost. Click Buy Now! Tab Above to request more information.

  • High performance amplifier certified for ATEX Hazardous Zones 0, 1 & 2
  • Designed for fitting in-line to strain gauge sensors such as load cells
  • Intrinsically Safe to EN60079-11
  • Environmentally sealed to IP67
  • Provides 2-wire 4-20mA current loop output
  • Fast calibration via gain and offset trim
  • Bridge impedance min 350 Ohms max 5000 Ohms
  • Wide temperature range -40C to +85C
  • Supplied with 1m strain gauge cable and 5m output cable
  • Robust design, reverse polarity & short circuit protected
  • OEM option available

Electrical & Environmental
Parameter Min Typ Max Units Notes
Supply Voltage Range
9
24
28
Volts
Operating Current
4
-
20
mA
Operating temperature range
-40
-
85
°C
Storage temperature range
-40
-
125
°C
Reverse polarity protection
-
-
-28
Volts
Measurement
Bridge excitation
1.05
1.11
1.16
Volts
1000 Ohms load cell connected
Bridge impedance
350
1000
5000
Ohms
Recommended bridge impedance is 1000 Ohms
Bridge sensitivity
0.5
2.5
55
mV/V
Factory setting is the typical value shown. For other values an alternative calibration resistor can be fitted (see manual).
Output current range
4
-
20
mA
Output load
-
-
800
Ohms
At 24V supply minimum
Bandwidth
DC
-
1000
Hz
Zero adjustment
-
±2
-
%FR
Span adjustment
-
±8
-
%FR
Linearity
-
0.02
-
%FR
Zero temp stability
-
0.001
0.005
±%FR/°C
Span temp stability
-
0.007
0.014
±%FR/°C
General Notes:
The voltage between either of the power supply connections and the load cell shield should not exceed 50V. Any leakage will be greater than 10M Ohms.
FR = Full Range
Documents Software
  • No Relevant Documents Available
ICA S & H
ICA S & H
Embedded strain gauge converter 4-20mA 0-5V 0-10V & ±10V
Q: What Strain Gauge parameters is the ALA5 designed for?

A: Designed for a 1k bridge, however, 350R can be used at the expense of noise and drift performance due to the reduced excitation voltage on the bridge. It is factory set for 2.5mV/V.

Q: What do the ATEX markings mean?

II 1 G Ex ia IIC T4
Tamb = -40°C to +85°C
CE0891 TRAC09ATEX1xxxX

ATEX Marking details

Explosion protection
II Equipment group: industrial
1 Equipment category: very high protection
G Hazard: gas atmosphere - zones 0,1 and 2

Certification Code details

Ex Explosion protection
ia Intrinsic safety according to EN60079-11 (previously EN 50020)
IIC Hydrogen/Acetylene gas group
T4 Temperature Classification – surface temperature <135°C



Q: Are there different mV/V settings available?

A: The sensitivity can be set between 0.5 mV/V and 55 mV/V by changing the SPAN (gain) resistor. Please enquire with our Sales team for more info.

Q: Can I extend the output cable on the ALA5?

A: Yes by use of an ATEX approved junction box.
Please note: The total cable capacitance must be taken into account and must not exceed TBD pF (pico farads).

Q: What is the maximum cable length for the load cell connections?

A: Maximum is 2 metres.

Q: Is a barrier needed for Zones 1 and 2?

A: Yes, a barrier is needed for all ATEX installations. Please contact us for more information.

Q: Can I embed the OEM device into my own loadcell?

A: Yes, the ICA5ATEX amplifier is designed to fit into a pocket in a certified loadcell.
Please note: OEM customers must hold a notified body Quality Assurance Notification (QAN) and ensure that the load cell and amplifier assembly is submitted for ATEX certification by an appropriate body.

PRODUCT ORDER OPTIONS
Item Number Description Order On-Line
     
ALA5 ATEX
4-20mA ATEX   (Intrinsically Safe)
Buy Now!
  • Introduction
  • Specifications
  • Dimensions
  • Downloads
  • Related Products
  • FAQ's
  • Buy Now!

ATEX Intrinsically Safe
ICA5ATEX 4-20mA 2 wire

The ATEX miniature load cell signal conditioner offers a high performance strain gauge amplifier in miniature format, designed specifically for fitting inside load cells, converting a standard load cell to a mA output.

Offering high stability and fast response.

Optional (ILE) in line enclosure to convert a standard load cell to a conditioned load cell output

ICA (models ICA1 - ICA6 S & H)

  • ATEX certificated strain gauge conditioner and load cell amplifier
  • Miniature PCB format for fitting inside sensors, 19mm diameter, 7.6mm height
  • 2 wire current loop 4-20mA output
  • Low interaction between the trimmers makes calibration fast and easy
  • High speed 1000 Hz
  • User selectable span and zero resistors
  • Robust design, high noise immunity & reverse polarity protected
  • Option of an in-line enclosure (shown on thumbnail image)

ICA5ATEX 4-20mA Current Output Amplifier

Electrical & Environmental
Parameter Min Typical Max Units/Notes
Supply Voltage Range
9.0
24
28
Volts
Operating Temp Range
-40
-
85
°C
Storage Temp Range
-40
-
85
°C
Reverse Polarity Protection
-30
-
-
Volts
Measurements
Bridge Excitation
1.05
1.11
1.16
Volts Note 1
Bridge Impedance
350
1000
5000
Ohms
Bridge Sensitivity
0.5
2.5
55
mV/V Note 2
Output Load
-
-
300
Ohms Note 3
Bandwidth
DC
-
1000
Hz
Zero Adjustment
-
±2
-
%FR Note 4
Span Adjustment
-
±8
-
%FR
Linearity
-
0.002
-
%FR
Temperature Stablity
Zero Temp Stability S
-
0.001
0.005
±%FR/°C
Span Temp Stability S
-
0.007
0.014
±%FR/°C

FR=Full Range (16mA)

Note 1: 1000 Ohm load cell – Typically 0.53V for 350 Ohm cell
Note 2: Set by calibration resistor
Note 3: Limited by the 300Ω barrier impedance
Note 4: 1000 Ohms load cell – change R1 to suit other load cell impedances.

Note: Recommended bridge impedance is 1,000 Ohms

Note: The voltage between either of the power supply connections and the load cell shield should not exceed 50V. Any leakage will be greater than 10M Ohms.

Environmental
Storage Temperature -40 to +85°C
Operating Temperature -40 to +85°C
Relative Humidity 95% maximum non condensing
CE Environmental Approvals European EMC Directive 2004/108/EC
 
     
Documents Software
  • No Relevant Documents Available
ALA-5
ALA-5
ATEX approved 4-20mA Amplifier for Hazardous Zones 0, 1 & 2
Q: What do the ATEX markings mean?

II 1 G Ex ia IIC T4
Tamb = -40°C to +85°C
CE0891 TRAC09ATEX1xxxX

ATEX Marking details

Explosion protection
II Equipment group: industrial
1 Equipment category: very high protection
G Hazard: gas atmosphere - zones 0,1 and 2

Certification Code details

Ex Explosion protection
ia Intrinsic safety according to EN60079-11 (previously EN 50020)
IIC Hydrogen/Acetylene gas group
T4 Temperature Classification – surface temperature <135°C



Q: Is a barrier needed for Zones 1 and 2?

A: Yes, a barrier is needed for all ATEX installations. Please contact us for more information.

Q: Can I embed the OEM device into my own loadcell?

A: Yes, the ICA5ATEX amplifier is designed to fit into a pocket in a certified loadcell.
Please note: OEM customers must hold a notified body Quality Assurance Notification (QAN) and ensure that the load cell and amplifier assembly is submitted for ATEX certification by an appropriate body.

Q: Are there different mV/V settings available?

A: The sensitivity can be set between 0.5 mV/V and 55 mV/V by changing the SPAN (gain) resistor. Please enquire with our Sales team for more info.

Q: Can I extend the output cable on the ALA5?

A: Yes by use of an ATEX approved junction box.
Please note: The total cable capacitance must be taken into account and must not exceed TBD pF (pico farads).

Q: What is the maximum cable length for the load cell connections?

A: Maximum is 2 metres.

Q: What Strain Gauge parameters is the ALA5 designed for?

A: Designed for a 1k bridge, however, 350R can be used at the expense of noise and drift performance due to the reduced excitation voltage on the bridge. It is factory set for 2.5mV/V.

PRODUCT ORDER OPTIONS
Item Number Description Order On-Line
     
ICALA5ATEX
ICA5ATEX- OEM 2 Wire 4-20mA ATEX
(Intrinsically Safe)
Buy Now!
Our On-Line Store provides a convenient way for you to purchase the items necessary for your needs, However if  don't see what you are looking for or would like to place an order by phone, please give us a call or email us.
Gear Merchant ● Phone: 404.353.8525 ● Email: gearinfo
Copyright © 2009 Gear Merchant All Rights Reserved  
Site Access Terms

    Visa
MasterCard
American Express
Discover