Browse by Store or Category
|
- ACQUISITION MODULES AND ENCLOSURES
- T24 ACM
Enclosure
- T24 ACMi
Mini-Enclosure
- T24 ACMm
Micro-Enclosure
- T24 IA
0-20mA Input
- T24 SA
mV/v Input
- T24 SAf
High-speed mV/v
- T24 VA
0-10v Input
- Introduction
- Specifications
- Dimensions
- Downloads
- Related Products
- FAQ's
- Buy Now!
|
- Sealed water-proofed enclosure for T24 Acquisition modules
- Allows for easy connection to sensor/load cell
- Provides battery holder and PSU for external power supply
- Easy connectivity with 2 part screw terminals
- Can provide battery backup to an external power supply
- Internal antenna provides up to 200m (650 ft) range
- Water-proofed IP65 NEMA4 enclosure
- Supplied as case only and requires acquisition modules - external antenna options are recommended T24-SA(e), T24-VA(e) and T24-IA(e)
|
| |
|
This module is a rugged enclosure for any of the T24 Acquisition modules and provides a battery holder and simple screw field terminals for easy wiring to a variety of sensors.
The module allows any of the T24 Acquisition modules to be powered either from the 2 x high capacity Alkaline D cell batteries or from an external supply. The batteries will act as backup if the external supply is lost.
The standard internal antenna supplied offers up to 200m (650 ft) range in an open field site.
The unit is supplied without the Acquisition Module (see T24-SA Strain, T24-VA Voltage, T24-IA Current). Upon ordering, it is recommended the 'external' antenna type (SAe, VAe, IAe) should be chosen to take advantage of the antenna supplied within this module.
See our T24-ACMi for a smaller enclosure designed for integration with sensors. Provides battery powering via 2 x AA Alkaline batteries |
| Electrical |
Min |
Typical |
Max |
Units |
| Battery Supply Voltage |
2.1 |
3.0 |
3.6 |
V DC |
| External Power Supply Voltage (optional use) |
5 |
- |
18 |
V DC |
| Environmental |
|
|
|
|
| IP Rating |
|
IP65 |
|
|
| Operating Temperature Range |
-40 |
|
+65* |
C |
| Storage temperature |
-40 |
|
+85 |
C |
| Humidity |
0 |
|
95 |
%RH |
| General Radio |
| Parameter |
Min |
Typical |
Max |
Units |
| Licence |
|
Licence Exempt |
|
|
| Modulation Method |
|
MS (QPSK) |
|
|
| Radio Type |
|
Transceiver (2 way) |
|
|
| Data Type |
|
250 |
|
K bits/sec |
| Radio Frequency |
2.4000 |
|
2.4835 |
GHz |
| Power |
|
1 |
|
mw |
| Integral Antenna |
|
|
100 (325) |
Meters (feet) ** |
| External Antenna |
|
|
200 (650) |
Meters (feet) ** |
| Channels (DSSS) |
|
16 |
|
|
| * Check operating temperature batteries intended for use. |
| **Maximum range achieved in open field site at height of 3 meters (9.8 feet) above ground. |
 |
Documents |
Software |
|
|
|
|
|
|
|
T24-SA |
|
|
|
|
Strain gauge to radio telemetry converter |
|
Voltage to wireless converter
|
|
Current to radio telemetry converter
|
|
|
|
|
|
|
|
|
|
|
T24-BSi |
|
|
|
|
Radio telemetry base station for USB RS485 RS232 |
|
Wireless radio telemetry USB base station
|
|
Telemetry data acquisition for strain, 0-20mA, 0-10V
|
No FAQ'S Posted at this Time..
| PRODUCT ORDER OPTIONS |
| Item Number |
Description |
Order On-Line |
| |
|
|
| T24-ACM |
Single Channel Acquisition Connectivity Module |
|
- Introduction
- Specifications
- Dimensions
- Downloads
- Related Products
- FAQ's
- Buy Now!
 |
- Miniature sealed enclosure for any of the T24 Acquisition module
- Provides complete battery powered telemetry unit
- Includes fitting for 2 x AA Alkaline batteries
- Easy connectivity with screw terminals for connection to a variety of sensors
- Internal antenna provides up to 200m (650 ft) range
- Water-proofed to IP65 NEMA4 enclosure
- Supplied as case only and requires acquisition modules – external antenna options are recommended T24-SA(e), T24-VA(e) and T24-IA(e)
|
 |
| |
|
This module is a miniature rugged enclosure for any of the T24 acquisition modules (strain, voltage or current) to provide protective water-proofing and powering. The unit has fitting for 2 x Alkaline AA batteries (not included) and simple screw field terminals for easy wiring to a variety of sensors.
The T24-ACMi is supplied with an IP68 cable gland although options are available for a cable connector or blanking plate if required for OEM applications.
The standard internal antenna supplied offers up to 200m (650 ft) range in an open field site.
The unit is supplied without the Acquisition Module. Upon ordering, it is recommended the 'external' antenna type (SAe, VAe, IAe) should be chosen to take advantage of the antenna supplied within this module. |
| Electrical |
Min |
Typical |
Max |
Units |
| Battery Supply Voltage |
2.1 |
3.0 |
3.6 |
V DC |
| Environmental |
|
|
|
|
| IP Rating |
|
IP65 |
|
|
| Operating Temperature Range |
-40 |
|
+80* |
C |
| Storage temperature |
-40 |
|
+85 |
C |
| Humidity |
0 |
|
95 |
%RH |
| General Radio |
| Parameter |
Min |
Typical |
Max |
Units |
| Licence |
|
Licence Exempt |
|
|
| Modulation Method |
|
MS (QPSK) |
|
|
| Radio Type |
|
Transceiver (2 way) |
|
|
| Data Type |
|
250 |
|
K bits/sec |
| Radio Frequency |
2.4000 |
|
2.4835 |
GHz |
| Power |
|
1 |
|
mw |
| Integral Antenna |
|
|
100 (325) |
Meters (feet) ** |
| External Antenna |
|
|
200 (650) |
Meters (feet) ** |
| Channels (DSSS) |
|
16 |
|
|
| *Check operating temperature of batteries intended for use. |
| **Maximum range achieved in open field site at height of 3 meters (9.8 feet) above ground |
 |
Documents |
Software |
|
|
|
|
|
|
|
|
|
|
|
T24-SAf |
Voltage to wireless converter
|
|
Current to radio telemetry converter
|
|
Strain gauge to radio telemetry converter 2kHz |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
T24-ACM |
Strain gauge to radio telemetry converter
|
|
Radio telemetry base station for USB RS485 RS232
|
|
Battery powered radio telemetry data acquisition module |
| Q: What is the difference between the ACM and ACMi? |
A: The T24-ACMi is physically smaller and provides power via 2 x AA batteries and has smaller terminal block style field connectors for wiring to acquisition modules. The T24-ACM although larger can provide power from an external power supply (5-18V) as well as 2 x D cell batteries which provide a higher battery capacity allowing for longer battery life.
|
| |
| Q: What Acquisition module fits with the ACM and ACMi? |
A: When using either ACM you will require an acquisition module that can accept an external antenna denoted by an ‘e’ on the end of the model name. Both ACM’s benefit from being fitted with a T24-ANTA which provides the best omni transmission range although higher gain and more directional antennas such as the T24-ANTC can also be fitted.
|
| PRODUCT ORDER OPTIONS |
| Item Number |
Description |
Order On-Line |
| |
|
|
| T24-ACMi |
Wireless Telemetry Acquisition Enclosure (Industrial Version) |
|
- Introduction
- Specifications
- Dimensions
- Downloads
- Related Products
- FAQ's
- Buy Now!
|
- Micro connectivity enclosure (20 x 35 x 76mm) IP54 rated
- Designed for integration to strain gauge, voltage or current input sensors to provide radio telemetry link
- Ideal for load cells, pressure, linear displacement, accelerometer, inclinometers & other current and voltage input sensors
- Provides complete battery powered radio telemetry unit
- Optional Battery Pack (T24-BB1)
- Easy connectivity with 2 part screw terminals for connection to a variety of sensors
- Internal antenna provides up to 100m (325 ft) range
- Electronics provide exceptionally low power for long battery life (up to 5 years)
- Remote power on and off
- High speed 200 Updates per second
- High Resolution of 1 part in 400,000 (18bit)
|
|
| |
|
The smallest of the T24 wireless telemetry connectivity modules providing connection to high performance wireless measurement electronics for strain gauge, pressure, load cell, linear displacement and other 4 wire bridge sensors. Also available as 0-10V voltage input or 0-20mA current input.
The standard internal antenna supplied offers up to 100m (325 ft) range in an open field site. Low power modes allow the module to power down between transmissions or to power off completely and can be controlled by other T24 products such as the handheld displays or base stations.
An optional battery pack can be chosen to power the T24-ACMm which uses 2 x AAA cells and can be connected to the ACMm via simple 2 part screw field terminals. Also offers the option to fit wired completion resistors allowing a strain input to be either full, half or quarter bridge input.
The high accuracy, low noise measurement electronics deliver high resolution, low drift results which can be user calibrated over 9 points to enable linearization and to deliver results in user definable engineering units. The results can be transmitted at rates up to 200 per second to other T24 devices such as handheld displays, analog outputs and base stations etc.
The module is configured and calibrated (either by applying known inputs or by table entry) using T24 Toolkit software which runs on a PC connected to a T24 base station.
The licence free 2.4GHz direct sequence spread spectrum (DSSS) radio technology offers high integrity, error free communications which can co-exist with other wireless technologies such as Wi-Fi, Bluetooth® and Zigbee®. FCC, ETSI and IC approvals.
The T24-ACMm-SA Strain version provides direct mV/V input and 5V bridge excitation for up to 4 load cells. |
| Electrical |
Min |
Typical |
Max |
Units |
| Battery Supply Voltage |
2.1 |
3.0 |
3.6 |
V DC |
| Environmental |
|
|
|
|
| IP Rating |
|
IP54 |
|
|
| Operating Temperature Range |
-40 |
|
+80* |
C |
| Storage temperature |
-40 |
|
+85 |
C |
| Humidity |
0 |
|
95 |
%RH |
| General Radio |
| Parameter |
Min |
Typical |
Max |
Units |
| Licence |
|
Licence Exempt |
|
|
| Modulation Method |
|
MS (QPSK) |
|
|
| Radio Type |
|
Transceiver (2 way) |
|
|
| Data Type |
|
250 |
|
K bits/sec |
| Radio Frequency |
2.4000 |
|
2.4835 |
GHz |
| Power |
|
1 |
|
mw |
| Integral Antenna |
|
|
100 (325) |
Meters (feet) ** |
| External Antenna |
|
|
200 (650) |
Meters (feet) ** |
| Channels (DSSS) |
|
16 |
|
|
| *Check operating temperature of batteries intended for use. |
| **Maximum range achieved in open field site at height of 3 meters (9.8 feet) above ground. |
|
Documents |
Software |
|
|
| ACQUISITION MODULES for Strain Gauge, 4-20mA & 0-10V |
|
|
|
|
|
T24-SA |
|
T24-IA |
|
T24-VA |
Strain gauge to radio telemetry converter |
|
Current to radio telemetry converter
|
|
Voltage to wireless converter
|
No FAQ'S Posted at this Time..
| PRODUCT ORDER OPTIONS |
| Item Number |
Description |
Order On-Line |
| |
|
|
T24-ACMm |
Wireless Telemetry Micro Connectivity Enclosure for Strain, Current or Voltage Input |
|
T24-BB1 |
Battery Pack |
|
- Introduction
- Specifications
- Dimensions
- Downloads
- Related Products
- FAQ's
- Buy Now!
|
- Radio telemetry acquisition module for 0-20mA current input
- Miniature PCB for fitting inside sensors
- Exceptionally low power for long battery life
- Remote power on and off
- High speed 200 updates per second
- High resolution of 1 part in 400,000 (18 bit)
- Simple configuration and calibration
- Antenna options giving up to 200m (650 ft) range
- Small cased version (shown on thumbnail image on left)
|
|
| |
|
This acquisition module provides wireless current measurement for an input range of 0-20mA. Suitable for a range of 4-20mA sensors such as pressure, inclinometer, accelerometer, temperature & displacement. The small module size allows for the option of embedding it within the sensor housing. Provides 5V sensor power.
Low power modes allow the module to power down between transmissions or to power off completely and can be controlled by other T24 products such as the handheld displays or a base station. The module can be configured to last several years on 2 x alkaline AA batteries or alternatively powered from 2 x NiMH or 1 x 3V Lithium.
The high accuracy, low noise measurement electronics deliver high resolution, low drift results which can be user calibrated over 9 points to enable linearization and to deliver results in user definable engineering units. The results can be transmitted wirelessly at rates up to 200 per second to other T24 devices such as handheld displays, analog outputs and base stations etc.
Although this module can be used as is for OEM solutions there are a number of enclosure options available. See ‘Related Products’ tab. The module is configured and calibrated (either by applying known inputs or by table entry) using free T24 Toolkit software which runs on a PC connected to a T24 base station.
Integral antenna option offers up to 100m (325 ft) range and external antenna options allows up to 200m (650 ft) range in an open field site.
The licence free 2.4GHz direct sequence spread spectrum (DSSS) radio telemetry technology offers high integrity, error free communications which can co-exist with other wireless technologies such as Wi-Fi, Bluetooth® and Zigbee®. FCC, ETSI and IC approvals. |
| General Radio |
Min |
Typical |
Max |
Units |
| Licence |
|
Licence Exempt |
|
|
| Modulation Method |
|
MS(QPSK) |
|
|
| Radio Type |
|
Transceiver (2 way) |
|
|
| Data Rate |
|
250 |
|
K bits/sec |
| Radio Frequency |
2.4000 |
|
2.4835 |
GHz |
| Power |
|
1 |
|
mw |
| Integral Antenna |
|
|
120 (400) |
Meters (feet) * |
| External Antenna |
|
|
200 (650) |
Meters (feet) * |
| Channels (DSSS) |
|
16 |
|
|
| *Maximum range achieved in open field site at a height of 3 meters (9.8 feet) above ground. |
| Specification at 3V supply at 25 Deg C |
| Input Range Sensitivity (FR) |
0 |
- |
21 |
mA |
| Calibrated Range |
4 |
- |
20 |
mA |
| Gain Temperature Stability |
- |
- |
50 |
ppm/C |
| Non Linerarity Before Linearization |
- |
5 |
25 |
ppm of FR |
| Internal Resolution |
- |
16,000,000/24 |
- |
Resolution/ Bits |
| Input Impedence |
- |
47 |
- |
Ohms |
| Input Calibration Accuracy |
- |
- |
0.1 |
%FR |
| Noise Free where Sample TIme < 10mS |
- |
5,000/12.5 |
|
Resolution/ Bits |
| Noise Free where Sample Time < 100mS |
- |
6,000/12.75 |
|
Resolution/ Bits |
| Noise Free where Sample Time < 1000mS |
- |
10,000/13.25 |
|
Resolution/ Bits |
| Noise Free where Sample Time > 1000mS |
- |
30,000/14.75 |
|
Resolution/ Bits |
| Electrical |
| Power Supply Voltage |
2.1 |
3.0 |
3.6 |
V dc |
| Power Supply Voltage |
|
|
50 |
mV ac pk-pk |
| Power Supply Current |
| Normal Mode on Constantly |
|
40 |
45 |
mA |
| Sleep Mode |
|
5 |
20 |
uA |
| Environmental |
| Operating Temperature Range |
-40 |
|
+85 |
C |
| Storage Temperature |
-40 |
|
+85 |
C |
| Humidity |
0 |
|
95 |
%RH |
| Battery Life in Low Power Mode Generating Results at 3Hz |
Usage |
Battery Life |
| Pair AA Cells |
Constantly On |
1 Month |
| Pair AA Cells |
12 sessions per day of 5 minutes |
2 Years |
| Pair D Cells |
Constantly On |
2.5 Months |
| Pair D Cells |
12 sessions per day of 5 minutes |
5 Years |
| |
Module transmits and Receives giving:
1. Full error detection and correction
2. Ability to switch to low power modes
3. Calibration & configuration via radio telemetry
4. Ability to be switched from sleep to operating mode via radio
5. Calibration stored within the module
6. Remote battery check |
 |
Documents |
Software |
|
|
|
|
|
|
|
T24-ACMi |
|
T24-ANT A,B,C, |
|
T24-A01 |
Telemetry data acquisition for strain, 0-20mA, 0-10V |
|
Antenna options for acquisition modules to extend range |
|
Radio telemetry data to analog output converter |
| |
|
|
|
|
|
|
|
|
|
T24-HA |
|
T24-HR |
|
T24-HS |
Radio telemetry handheld display up to 12 inputs |
|
Radio telemetry handheld for multiple acquisition modules |
|
Radio telemetry portable display for 1 wireless sensor |
| |
|
|
|
|
|
|
|
|
|
T24-SO |
|
T24-PR1 |
|
T24-RM1 |
Radio telemetry input, data output for displays and printers |
|
Radio telemetry data printer |
|
Radio telemetry data to relay output |
Q: What are the sampling rates of the acquisition modules?
A: The T24 standard acquisition modules (SA, IA, VA) sample from 0-200 updates/sec. The T24 fast acquisition modules are fixed at 2,000 updates/sec.
Q: What is the resolution of the acquisition modules?
A: The noise free resolution for a sample time of 10 milli-seconds or less is 15.5 bits for the T24 SA, 12.5 bits for the T24-VA and 12.25 bits for the T24IA. With increased sample times resolution can be increased up to 18.75 bits for the T24-SA.
Q: What is the supply voltage for the acquisition modules?
A: 3V for the acquisition modules and handheld displays. Other modules in the range take 9-36 V.
Q: What is the difference between the i and e versions of the acquisition units?
A: The i modules T24-SAi, (T24-SAfi, T24-VAi, T24-IAi) all feature an on chip integrated antenna. The e modules (T24-SAe, T24-SAfe, T24-VAe, T24-IAe) are fitted with a miniature UFL connector which can be used with any of the antenna options available; the T24-ANTA (PCB antenna) or T24-ANTB (fixed 90 degree Whip antenna) or T24-ANTC (flexible whip antenna).
Q: How are the modules powered?
A: Two standard AA batteries or the T24-BC1 Battery Charger, which provides a re-chargeable power supply using a Li-ion Cell. Find out the battery life of your system using our Battery Calculator.
Q: What inputs are available to the T24 system?
A: T24-SA 2.5mV/V calibrated strain gauge based measurement; T24-VA 0-10V, T24-IA 4-20mA.
For more Frequently Asked Questions please see our Knowledge Center Click here |
| PRODUCT ORDER OPTIONS |
| Item Number |
Description |
Order On-Line |
| |
|
|
T24-IAe |
Current Acquisition with fitting for External Antenna (not incl) |
|
T24-IAi |
Current Acquisition with Internal Antenna |
|
- Introduction
- Specifications
- Dimensions
- Downloads
- Related Products
- FAQ's
- Buy Now!
 |
- Strain gauge to radio telemetry converter
- Miniature PCB for fitting inside sensors such as load cells
- Exceptionally low power for long battery life (up to 5 years)
- Remote power on and off
- High speed 200 Updates per second
- High Resolution of 1 part in 400,000 (18bit)
- In-built antenna
- Simple wireless configuration and calibration
- Antenna options giving up to 200m (650 ft) range
- Choice of enclosure versions available
- (see left and Related Products) - T24-ACMm, T24-ACMi & T24-ACM)
|
| |
|
| |
|
T24- Enclosure Options |
| |
This remote acquisition module provides high performance wireless measurement of strain gauge, pressure, load cell, linear displacement and other 4 wire bridge sensors. Providing direct mV/V input and 5V bridge excitation for up to 4 load cells. The miniature size allows for the option of embedding within the sensor housing.
Low power modes allow the module to power down between transmissions or to power off completely and can be controlled by other T24 products such as the handheld displays or a base station. The module can be configured to last several years on 2 x alkaline AA batteries or alternatively be powered from 2 x NiMH or 1 x 3V Lithium.
The high accuracy, low noise measurement electronics deliver high resolution, low drift results which can be user calibrated over 9 points to enable linearization and to deliver results in user definable engineering units. The results can be transmitted at rates up to 200 per second to other T24 devices such as handheld displays, analog outputs and base stations etc.
Although this module can be used as an OEM solution (for example creating a wireless load cell by embedding the module), there are enclosure options available (see T24-ACM in Related Products Tab).
The module is configured and calibrated (either by applying known inputs or by table entry) using free T24 Toolkit software which runs on a PC connected to a T24 base station.
Integral antenna option offers up to 100m (325 ft) range and external antenna options allows up to 200m (650 ft) range in an open field site.
The licence free 2.4GHz direct sequence spread spectrum (DSSS) radio technology offers high integrity, error free communications which can co-exist with other wireless technologies such as Wi-Fi, Bluetooth® and Zigbee®. FCC, ETSI and IC approvals |
| General Radio |
Min |
Typical |
Max |
Units |
| Licence |
|
Licence Exempt |
|
|
| Modulation Method |
|
MS (QPSK) |
|
|
| Radio Type |
|
Transceiver (2 way) |
|
|
| Data Rate |
|
250 |
|
k bits/sec |
| Radio Frequency |
2.4000 |
|
2.4835 |
GHz |
| Power |
|
1 |
|
mw |
| Integral Antenna |
|
|
100 (325) |
Meters (feet) * |
| External Antenna |
|
|
200 (650) |
Meters (feet) * |
| Channels (DSSS) |
|
16 |
|
|
| *Maximum range achieved in open field site at height of 3 meters (9.8 feet) above ground. |
| T24-SA |
|
|
|
|
| Specifications with 1000R bridge, 2.5mV/V, at 3V supply at 25 Deg C |
| Strain Gauge Excitation System |
|
4 wire |
|
|
| Strain Gauge Excitation Voltage |
4.5 |
5 |
5.25 |
VDC |
| Strain Gauge Drive Capacity |
85 |
- |
5000 |
Ohms |
| Maximum Gauge Sensitivity (FR) |
|
|
3.2 |
±mV/V |
| Offset Temperature Stability |
|
1 |
4 |
ppm/C |
| Gain Temperature |
|
3 |
5 |
ppm/C |
| Offset Stability with Time |
|
20 |
80 |
ppm of FR (1) |
| Gain Stability with Time |
|
|
30 |
ppm of FR (2) |
| Non Linearity before Linearization |
|
5 |
25 |
ppm of FR |
| Internal Resolution |
|
16,000,000/24 |
|
Resolution/bits |
| Noise Free where Sample Time < 10mS |
|
50,000/15.5 |
|
Resolution/bits |
| Noise Free where Sample Time < 50mS |
|
65,000/16 |
|
Resolution/bits |
| Noise Free where Sample Time < 100mS |
|
150,000/17.25 |
|
Resolution/bits |
| Noise Free where Sample Time < 1000mS |
|
250,000/18 |
|
Resolution/bits |
| Noise Free where Sample Time < 10000mS |
|
400,000/18.75 |
|
Resolution/bits |
| Electrical |
|
|
|
|
| Power Supply Voltage |
2.1 |
3.0 |
3.6 |
VDC |
| Power Supply Ripple |
|
|
50 |
mV ac pk-pk |
| Power Supply Current |
|
|
|
|
| Normal Mode (1K Bridge) |
|
60 |
65 |
mA |
| Standby/Low Power Mode |
|
5 |
20 |
uA |
| Environment |
|
|
|
|
| Operating Temperature Range |
-40 |
|
+85 |
C |
| Storage Temperature Range |
-40 |
|
+85 |
C |
| Humidity |
0 |
|
95 |
%RH |
| |
Module transmits and Receives giving:
1. Full error detection and correction
2. Calibration & configuration via radio telemetry
3. Ability to be switched from sleep to operating mode via radio
4. mV/V Calibration stored within the module
5. Remote battery check
6. Data Encryption for complete security (128 bit AES) |
| |
 |
Documents |
Software |
|
|
 |
|
 |
|
 |
|
 |
| T24-BSu |
|
T24-HA |
|
T24-HR |
|
T24-HS |
| Wireless radio telemetry USB base station |
|
Radio telemetry handheld display up to 12 inputs |
|
Radio telemetry handheld for multiple acquisition modules |
|
Radio telemetry portable display for 1 wireless sensor |
|
|
|
|
|
|
|
 |
|
 |
|
 |
|
 |
| T24-A01 |
|
T24-SO |
|
T24-PR1 |
|
T24-RM1 |
| Radio telemetry data to analog output converter |
|
Radio telemetry input, data output for displays and printers |
|
Radio telemetry data printer |
|
Radio telemetry data to relay output |
|
|
|
|
|
|
|
 |
|
 |
|
 |
|
 |
| T24-ANT A,B,C, |
|
T24-BC1 |
|
T24-ACMi |
|
T24-ACMm |
| Antenna options for acquisition modules to extend range |
|
Lithium Ion battery charger for T24 acquisition modules |
|
Telemetry data acquisition for strain, 0-20mA, 0-10V |
|
Micro telemetry data acquisition for strain, 0-20mA, 0-10V |
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
| T24-ACM |
|
|
|
|
|
|
| Battery powered radio telemetry data acquisition module |
|
|
|
|
|
|
|
|
|
|
|
|
|
- Q: What are the sampling rates of the acquisition modules?
-
A: The T24 standard acquisition modules (SA, IA, VA) sample from 0-200 updates/sec. The T24 fast acquisition modules are fixed at 2,000 updates/sec.
- Q: What is the resolution of the acquisition modules?
-
A: The noise free resolution for a sample time of 10 milli-seconds or less is 15.5 bits for the T24 SA, 12.5 bits for the T24-VA and 12.25 bits for the T24IA. With increased sample times resolution can be increased up to 18.75 bits for the T24-SA.
- Q: What is the supply voltage for the acquisition modules?
-
A: 3V for the acquisition modules and handheld displays. Other modules in the range take 9-36 V.
- Q: What is the difference between the T24-SA and T24-SAf?
-
A: The standard acquisition modules are capable of providing data up to 200Hz. The fast T24-SAf provides data at a fixed 2Khz.
- Q: What is the difference between the i and e versions of the acquisition units?
-
A: The i modules (T24-SAi, T24-SAfi, T24-VAi, T24-IAi) all feature an on chip
integrated antenna. The e modules (T24-SAe, T24-SAfe, T24-VAe, T24-IAe) are
fitted with a miniature UFL connector which can be used with any of the antenna options available; the T24-ANTA (PCB antenna) or T24-ANTB (fixed 90 degree Whip antenna) or T24-ANTC (flexible whip antenna).
- Q: How are the strain gauge acquisition modules calibrated?
-
A: The modules are factory calibrated to 2.5 mV/V which can be custom calibrated and linearised over up to 9 points by using the T24 Toolkit.
- Q: How are the modules powered?
-
A: Two standard AA batteries or the T24-BC1 Battery Charger, which provides a re-chargeable power supply using a Li-ion Cell.
-
-
- Q: What inputs are available to the T24 system?
-
A: T24-SA 2.5mV/V calibrated strain guage based measurement; T24-VA 0-10V, T24-IA 4-20mA.
There are other terms which may help to describe this product and is capabilities. These are:
- wireless strain gauge
- wireless strain gage
- wireless sensor
- loadcell wireless sensor network
- wireless sensors network
- radio sensor network
- digital telemetry
- remote data logging
- multi channel data logger
- telemetry data logger
- radio telemetry
- telemetry system
- telemetry monitoring
- wireless telemetry
- wireless data acquisition
- remote data acquisition
Other common terms used in industry are also:
- vehicle weighing
- torque telemetry
- load cell telemetry interface
- load cell wireless interface
- load cell radio system
- wireless load cell
- wireless crane scale
- wireless vehicle weighing
- crane scale
- vehicle weighing
Links
Wireless Strain Gauge
Radio Sensor Network
|
| PRODUCT ORDER OPTIONS |
| Item Number |
Description |
Order On-Line |
| |
|
|
T24-SAi |
Strain Acquisition with fitting with Internal Antenna |
|
T24-SAe |
Strain Acquisition with fitting for External Antenna |
|
- Introduction
- Specifications
- Dimensions
- Downloads
- Related Products
- FAQ's
- Buy Now!
|
- Wireless acquisition module for strain gauge based sensor measurements such as load cells
- Ultra fast update rate of 2000 per second
- Miniature PCB for fitting inside sensors
- Exceptionally low power for long battery life (up to 5 years)
- Remote power on and off
- Factory calibrated measurement
- Simple wireless configuration and calibration
- Antenna options giving up to 200m (650 ft) range
- Small cased version available (shown on thumbnail image on left)
|
| |
|
| |
This acquisition module provides high speed measurement of strain gauge, pressure, linear displacement and other strain gauge based sensors including loadcells. The small module size allows for the option of embedding it within the sensor housing.
Low power modes allow the module to power off completely and can be controlled by other T24 products such as the handheld displays or a base station. The module can be configured to last several years on 2 x alkaline AA batteries or alternatively powered from 2 x NiMH or 1 x 3V Lithium.
The high speed electronics deliver low drift results which are transmitted at a rate of 2000 readings per second to other T24 devices such as analog outputs and base stations etc.
Although this module can be used ‘as is’ for OEM solutions there are a number of enclosure options available. See Related Products tab.
Integral antenna option offers up to 100m (325 ft) range and external antenna options allows up to 200m (650 ft) range in an open field site. The module is configured using free T24 Toolkit software which runs on a PC connected to a T24 base station.
The licence free 2.4GHz direct sequence spread spectrum (DSSS) radio technology offers high integrity, error free communications which can co-exist with other wireless technologies such as Wi-Fi, Bluetooth® and Zigbee®. FCC, ETSI and IC approvals. |
| General Radio |
Min |
Typical |
Max |
Units |
| Licence |
|
Licence Exempt |
|
|
| Modulation Method |
|
MS (QPSK) |
|
|
| Radio Type |
|
Transceiver (2 way) |
|
|
| Data Rate |
|
250 |
|
k bits/sec |
| Radio Frequency |
2.4000 |
|
2.4835 |
GHz |
| Power |
|
1 |
|
mw |
| Integral Antenna |
|
|
100 (325) |
Metres (feet) * |
| External Antenna |
|
|
200 (650) |
Metres (feet) * |
| Channels (DSSS) |
|
16 |
|
|
| *Maximum range achived in open field site at height of 3 metres (9.8 feet) above ground. |
| T24-SAf |
| Specifications with 1000R bridge, 2.5mV/V, at 3V supply at 25 Deg C |
| Strain Gauge Excitation System |
|
4 wire |
|
|
| Strain Gauge Excitation Voltage |
4.5 |
5 |
5.25 |
VDC |
| Strain Gauge Drive Capacity |
85 |
- |
5000 |
Ohms |
| Maximum Gauge Sensitivity (FR) |
|
|
3.2 |
±mV/V |
| Offset Temperature Stability |
|
1 |
4 |
ppm/C |
| Gain Temperature |
|
3 |
5 |
ppm/C |
| Offset Stability with Time |
|
20 |
80 |
ppm of FR (1) |
| Gain Stability with Time |
|
|
30 |
ppm of FR (2) |
| Non Linearity before Linearization |
|
5 |
25 |
ppm of FR |
| Noise free resolution (10 Second Sample) |
|
8000/13 |
|
Resolution/bits |
| Electrical |
| Power Supply Voltage |
2.1 |
3.0 |
3.6 |
VDC |
| Power Supply Ripple |
|
|
50 |
mV ac pk-pk |
| Power Supply Current |
| Normal Mode (1K Bridge) |
|
60 |
65 |
mA |
| Standby/Low Power Mode |
|
5 |
20 |
uA |
| Power Supply |
| Active |
|
35 |
40 |
mA |
| Sleep Mode (1K Bridge) |
|
5 |
20 |
mA |
| Estimated Battery Life using 24hr batteries: |
|
|
|
|
| Standby Mode (Powered off) |
|
1.5 |
|
Years |
| Continuous Operation |
|
40 |
|
Hours |
| Environment |
| Operating Temperature Range |
-40 |
|
+85 |
C |
| Storage Temperature Range |
-40 |
|
+85 |
C |
| Humidity |
0 |
|
95 |
%RH |
| |
Module transmits and Receives giving:
1. Full error detection and correction
2. Calibration & configuration via radio telemetry
3. Ability to be switched from sleep to operating mode via radio
4. mV/V Calibration stored within the module
5. Remote battery check
6. Data Encrytion for complete security (128 bit AES) |
 |
Documents |
Software |
|
|
 |
|
 |
|
 |
|
 |
| T24-AO |
|
T24-HA |
|
T24-HR |
|
T24-HS |
| Radio telemetry data to analog output converter |
|
Radio telemetry handheld display up to 12 inputs |
|
Radio telemetry handheld for multiple acquisition modules |
|
Radio telemetry portable display for 1 wireless sensor |
|
|
|
|
|
|
|
 |
|
 |
|
 |
|
 |
| T24-ACMi |
|
T24-ANT A,B,C, |
|
T24-PR1 |
|
T24-RM1 |
| Telemetry data acquisition for strain, 0-20mA, 0-10V |
|
Antenna options for acquisition modules to extend range |
|
Radio telemetry data printer |
|
Radio telemetry data to relay output |
- Q: What are the sampling rates of the acquisition modules?
-
A: The T24 standard acquisition modules (SA, IA, VA) sample from 0-200 updates/sec. The T24 fast acquisition modules are fixed at 2,000 updates/sec.
- Q: What is the resolution of the acquisition modules?
-
A: The noise free resolution for a sample time of 10 milli-seconds or less is 15.5 bits for the T24 SA, 12.5 bits for the T24-VA and 12.25 bits for the T24IA. With increased sample times resolution can be increased up to 18.75 bits for the T24-SA.
- Q: What is the supply voltage for the acquisition modules?
-
A: 3V for the acquisition modules and handheld displays. Other modules in the range take 9-36 V.
- Q: What is the difference between the T24-SA and T24-SAf?
-
A: The standard acquisition modules are capable of providing data up to 200Hz. The fast T24-SAf provides data at a fixed 2Khz.
- Q: What is the difference between the i and e versions of the acquisition units?
-
A: The i modules (T24-SAi, T24-SAfi, T24-VAi, T24-IAi) all feature an on chip
integrated antenna. The e modules (T24-SAe, T24-SAfe, T24-VAe, T24-IAe) are
fitted with a miniature UFL connector which can be used with any of the antenna options available; the T24-ANTA (PCB antenna) or T24-ANTB (fixed 90 degree Whip antenna) or T24-ANTC (flexible whip antenna).
- Q: How are the strain gauge acquisition modules calibrated?
-
A: The modules are factory calibrated to 2.5 mV/V which can be custom calibrated and linearised over up to 9 points by using the T24 Toolkit.
- Q: How are the modules powered?
-
A: Two standard AA batteries or the T24-BC1 Battery Charger, which provides a re-chargeable power supply using a Li-ion Cell.
|
| PRODUCT ORDER OPTIONS |
| Item Number |
Description |
Order On-Line |
| |
|
|
T24-SAfi |
Fast Strain Acquisition with fitting with Internal Antenna |
|
T24-SAfe |
Fast Strain Acquisition with fitting for External Antenna |
|
- Introduction
- Specifications
- Dimensions
- Downloads
- Related Products
- FAQ's
- Buy Now!
|
- Wireless radio telemetry acquisition module for 0-10Volt input
- Miniature PCB for fitting inside sensors
- Exceptionally low power for long battery life
- Remote power on and off
- High speed 200 updates per second
- High resolution of 1 part in 15,000 (13.75 bit)
- Simple wireless configuration and calibration
- Antenna options giving up to 200m (650 ft) range
- Choice of enclosure versions available
- (see left and Related Products) - T24-ACMm, T24-ACMi & T24-ACM)
|
| |
|
|
| |
This acquisition module provides wireless voltage measurement for an input range of 0 to 10Volts. Suitable for a range of 0-10V sensors including pressure, inclinometer, accelerometer, temperature & displacement. The small module size allows for the option of embedding it within the sensor housing. Provides 5V sensor power.
Low power modes allow the module to power down between transmissions or to power off completely and can be controlled by other T24 products such as the handheld displays or a base station. The module can be configured to last several years on 2 x alkaline AA batteries or alternatively powered from 2 x NiMH or 1 x 3V Lithium.
The high accuracy, low noise measurement electronics deliver high resolution, low drift results which can be user calibrated over 9 points to enable linearization and to deliver results in user definable engineering units. The results can be transmitted at rates up to 200 per second to other T24 devices such as handheld displays, analog outputs and base stations etc.
Although this module can be used as is for OEM solutions there are a number of enclosure options available. See Related Products tab.
The module is configured and calibrated (either by applying known inputs or by table entry) using free T24 Toolkit software which runs on a PC connected to a T24 base station.
Integral antenna option offers up to 100m (325 ft) range and external antenna options allows up to 200m (650 ft) range in an open field site.
The licence free 2.4GHz direct sequence spread spectrum (DSSS) radio technology offers high integrity, error free communications which can co-exist with other wireless technologies such as Wi-Fi, Bluetooth® and Zigbee®. FCC, ETSI and IC approvals. |
| General Radio |
Min |
Typical |
Max |
Units |
| Licence |
|
Licence Exempt |
|
|
| Modulation Method |
|
MS(QPSK) |
|
|
| Radio Type |
|
Transceiver (2 way) |
|
|
| Data Rate |
|
250 |
|
K bits/sec |
| Radio Frequency |
2.4000 |
|
2.4835 |
GHz |
| Power |
|
1 |
|
mw |
| Integral Antenna |
|
|
120 (400) |
Metres (feet) * |
| External Antenna |
|
|
200 (650) |
Metres (feet) * |
| Channels (DSSS) |
|
16 |
|
|
| *Maximum range achieved in open field site at a height of 3 metres (9.8 feet) above ground. |
| Specification at 3V supply at 25 Deg C |
| Input Range Sensitivity (FR) |
0 |
- |
10 |
Volts |
| Gain Temperature Stability |
- |
- |
50 |
ppm/C |
| Non Linerarity Before Linearization |
- |
5 |
25 |
ppm of FR |
| Internal Resolution |
- |
16,000,000/24 |
- |
Resolution/ Bits |
| Input Impedence |
- |
100,000 |
- |
Ohms |
| Input Calibration Accuracy |
- |
- |
0.1 |
%FR |
| Noise Free where Sample TIme < 10mS |
- |
5,000/12.25 |
|
Resolution/ Bits |
| Noise Free where Sample Time < 100mS |
- |
8,000/13.0 |
|
Resolution/ Bits |
| Noise Free where Sample Time < 1000mS |
- |
11,000/13.5 |
|
Resolution/ Bits |
| Noise Free where Sample Time > 1000mS |
- |
15,000/13.75 |
|
Resolution/ Bits |
| Electrical |
| Power Supply Voltage |
2.1 |
3.0 |
3.6 |
V dc |
| Power Supply Voltage |
|
|
50 |
mV ac pk-pk |
| Power Supply Current |
| Normal Mode on Constantly |
|
40 |
45 |
mA |
| Sleep Mode |
|
5 |
20 |
uA |
| Environmental |
| Operating Temperature Range |
-40 |
|
+85 |
C |
| Storage Temperature |
-40 |
|
+85 |
C |
| Humidity |
0 |
|
95 |
%RH |
| |
|
|
|
|
Module transmits and Receives giving:
1. Full error detection and correction
2. Ability to switch to low power modes
3. Calibration & configuration via radio telemetry
4. Ability to be switched from sleep to operating mode via radio
5. Calibration stored within the module
6. Remote battery check |
  |
Documents |
Software |
|
|
 |
|
 |
|
 |
|
 |
| T24-A01 |
|
T24-HA |
|
T24-HR |
|
T24-HS |
| Radio telemetry data to analog output converter |
|
Radio telemetry handheld display up to 12 inputs |
|
Radio telemetry handheld for multiple acquisition modules |
|
Radio telemetry portable display for 1 wireless sensor |
|
|
|
|
|
|
|
 |
|
 |
|
 |
|
 |
| T24-ACMi |
|
T24-SO |
|
T24-PR1 |
|
T24-RM1 |
| Telemetry data acquisition for strain, 0-20mA, 0-10V |
|
Radio telemetry input, data output for displays and printers |
|
Radio telemetry data printer |
|
Radio telemetry data to relay output |
- Q: What are the sampling rates of the acquisition modules?
-
A: The T24 standard acquisition modules (SA, IA, VA) sample from 0-200 updates/sec. The T24 fast acquisition modules are fixed at 2,000 updates/sec.
- Q: What is the resolution of the acquisition modules?
-
A: The noise free resolution for a sample time of 10 milli-seconds or less is 15.5 bits for the T24 SA, 12.5 bits for the T24-VA and 12.25 bits for the T24IA. With increased sample times resolution can be increased up to 18.75 bits for the T24-SA.
- Q: What is the supply voltage for the acquisition modules?
-
A: 3V for the acquisition modules and handheld displays. Other modules in the range take 9-36 V.
- Q: What is the difference between the T24-SA and T24-SAf?
-
A: The standard acquisition modules are capable of providing data up to 200Hz. The fast T24-SAf provides data at a fixed 2Khz.
- Q: What is the difference between the i and e versions of the acquisition units?
-
A: The i modules (T24-SAi, T24-SAfi, T24-VAi, T24-IAi) all feature an on chip
integrated antenna. The e modules (T24-SAe, T24-SAfe, T24-VAe, T24-IAe) are
fitted with a miniature UFL connector which can be used with any of the antenna options available; the T24-ANTA (PCB antenna) or T24-ANTB (fixed 90 degree Whip antenna) or T24-ANTC (flexible whip antenna).
- Q: How are the strain gauge acquisition modules calibrated?
-
A: The modules are factory calibrated to 2.5 mV/V which can be custom calibrated and linearised over up to 9 points by using the T24 Toolkit.
- Q: How are the modules powered?
-
A: Two standard AA batteries or the T24-BC1 Battery Charger, which provides a re-chargeable power supply using a Li-ion Cell. Find out the battery life of your system using our Battery Calculator.
- Q: What inputs are available to the T24 system?
-
A: T24-SA 2.5mV/V calibrated strain guage based measurement; T24-VA 0-10V, T24-IA 4-20mA.
|
| PRODUCT ORDER OPTIONS |
| Item Number |
Description |
Order On-Line |
| |
|
|
T24-VAe |
Voltage Acquisition with fitting for External Antenna (not incl) |
|
T24-VAi |
Voltage Acquisition with Internal Antenna |
|
|